Conceptpower UPS |
|
|
|
A brief guide to UPS-Technology |
|
|
Second generation transformerless three phase UPS in the range 60-300kVA protects your mission critical
load and your environment
Large and heavy traditional UPS systems have been in the market for a long time. Big and bulky accessories like 12pulse rectifiers and input harmonic
filters are used to improve the input power factor and the input current THD in order not to pollute the mains. The consequences are increased
expensive floor-space, increased power losses throughout the lifecycle of the UPS and increased audible noise.
In the past decade we have experienced very modest qualitative technological improvements with clear end-user benefits in the area of high
power UPS’s. Environmentally conscious customers today are not only demanding highest power protection availability but also systems that are
environmentally friendly and ensure low cost of ownership.
WE COMPLETE
Protects not only your critical load but also your environment during the entire UPS lifecycle.
ConceptpowerTM is an advanced double
conversion, VFI (Voltage and Frequency
Independent) technology that responds fully
to both highest availability and environmentally
friendly requirements. In other words
the conceptpowerTM simultaneously
protects your critical load and your environment.
Furthermore your cost of ownership
will be low during the entire lifecycle of the
UPS system. Thanks to the unique and
highest threephase double conversion
efficiency, low mains harmonic pollution, low
audible noise and optimized material contents
conceptpowerTM is a true green UPS.
The proven Newave double conversion
technology guarantees highest reliability and
unmatched electrical performance. If we add
to the above features the unique Distributed
Parallel Architecture (DPA) for redundancy
and for extension of power capacity it will
complete the picture of this exciting power
protection system.
Conceptpower ups N+1 redundant, three-phase power protection concept designed for easy and quick service-ability to maximize power availability.
Modules Power range: 10-15-20-30-40-60-80-100 kVA three phase (infinitely expandable)
Topology: On-Line, double conversion, VFI
Features at a glance:
- Infinitely expandable
- Highest availability
- Hot-swappable
- Front access only
- Low Mean Time To Repair (MTTR)
- Input Power Factor PF = 0.98
- Less than 7% THDI at the input
- Up to 96% efficiency in On-Line mode, and 98% efficiency in eco-mode
- Ripple-free battery increase battery life
- Wide input frequency range (35-70 Hz)
- Wide input voltage range (-25% /+15%)
Keep a constant eye on your environment and your cost of ownership
ConceptpowerT was designed to meet also important environmental demands and to focus on the cost of ownership of a power protection infrastructure. Feaures like low heat emission, low level of harmonic pollution and low level audible noise are part of the Power Protection Concept (PPC) and have been built into ConceptpowerT design.
|
 |
|
|

|
High Efficiency
High ConceptpowerT efficiency means low heat emission and therefore low cost waste of energy consumption. Furthermore the heat must always be evacuated by cooling systems, which must be sized to the amount of losses emitted by the UPS's. That is also a cost that must be considered during the entire lifecycle of the UPS. Thanks to the transformerless technology and the unique ESIS (Energy Saving Inverter Switching), the ConceptpowerT reaches double conversion efficiency up to 97%. This advanced high efficiency design has in average at least 5% higher efficiency than equivalent traditional double conversion designs. |

|
High Input Power Factor / Sinewave Input Current
The near to one input power factor of ConceptpowerT reduces the input installation cost by using smaller cable sections and smaller fuse size. Thanks to the low input current THDI < 7% (sinewave input current) the level of harmonic pollution of the ConceptpowerT is very low and saves unnecessary oversizing of the gen-sets.
The near to one power factor and the low THDI of ConceptpowerT are electronically regulated and there is therefore no need for expensive filtering or 12 pulse rectification like in the traditional double conversion topologies.
|

Legacy UPS with high ripple contents

ConceptpowerT UPS with ripple-free
|
Battery protection and Battery management
ConceptpowerT is provided with a unique ripple-free battery charger that protects the battery from overheating and consequently increase the battery lifecycle. A further battery protection feature is the temperature regulated battery charge voltage where the voltage is ambient temperature dependent. The built-in Flexible Battery Management (FBM) periodically and automatically checks the fitness of the battery and alerts immediately if any anomaly appears. The FBM allows the use of a flexible number of battery blocks providing the exact battery runtime optimizing the battery cost. |
|
|
|
|
|
|
|